The patch-panel may be accessed remotely over a TCP/IP link using Telnet. This allows the user to create / patch new circuits remotely and make new E1 cross-connections on the fly. SNMP V2 access is also available over UDP link, which allows the user to monitor the patch-panel and all E1 circuits remotely for any alarms. An MIB file is provided with the patch-panel to allow easy integration with customer’s network management systems (NMS), or for easy integration with standard SNMP browsers.
Rack Mounting | Standard 19 Inch. DIN Rack |
Height | 90 mm. |
Depth | 45 mm. |
Width | 485 mm. (with mounting brackets) |
Weight | 1.4 kg. |
Product Part Number: VCL-1240-MON-120-100-RJ45F-16
Product Description: 16xE1/T1, 120/100 Ohms RJ45 (F) High Impedance (Hi-Z) Monitoring Patch Panel 19" Shelf 2U High Mount version with Hardware Set [RJ45 cables not included]
All four DIP switches must be set to OFF position for non-intrusive monitoring applications.
The Hi-Z (432 Ohm) resistive output is provided on the Monitoring (MON) Port of the Patch Panel for connecting to the Groomer / Probe / Analyser.
The RJ-45 Connectors Row A and Row B are used for Data IN/Data OUT from/to the Site A and Site B E1 link.
The RJ-45 Connectors Row MON are used for Hi-Z Data OUT from the E1 link connected on Row A and Row B to E1 Groomers, Probes or Analysers.
Valiant Communications is an ISO 9001:2015, ISO 10001:2018, ISO 14001:2015, ISO 27001:2022 and ISO 45001:2018 certified equipment manufacturer.
Teleprotection over E1, C37.94,
MPLS-TP, MPLS / IP, IEC-61850 GOOSE
VCL-PMU-30, Phasor Measurement Unit (PMU)
VCL-PDC, Phasor Data Concentrator (PDC)
GPS / GNSS, Primary Reference Clocks (G.811)
PTP IEEE-1588v2 Grandmaster, PTP Slave, PTP Transparent Clock
GPS to IRIG-B, GPS to 1PPS Servers
Time Distribution, IRIG-B, 1PPS, RS-232 / RS-485
SDH with MPLS-TP & SONET Multiplexers
E1 PDH & Digital Cross Connect
IP over TDM / Ethernet over TDM
TDM over IP / Ethernet / Packet / MPLS
E1 / T1, 1+1 Automatic Protection / Failover
1+1 Ethernet Failover / AB Fallback Switch
Groomer (Hi-Z Non-Intrusive Monitoring) - E1, T1 and STM-1
E1 and T1 Echo Cancellers & VQE
Serial to Ethernet and MODBUS Converters
Patch Panels, AC DC Converters, Passive Products