VCL Products > Electronic Patch Panels
E1 and T1 Intelligent Electronic Patch Panels
and Patch Panels with High Impedance (Hi-Z) Monitoring Ports
Valiant offers a wide range of Electronic E1 120 Ohms / T1 100 Ohms / E1 75 Ohms Patch Panels and High Impedance (Hi-Z) Monitoring Patch Panels. Valiant also offers a wide range of 75 Ohms connector options to suit the wide connector options available in the market place. These 75 Ohms connector options include: 75 Ohms with BNC, BT43, M4 (Male), M4 (Female), Siemens (1.6/5.6 Female) Connector options. Please ask for data sheet for any of these various 75 Ohms connector options.
16 E1, 120 Ohms, Patch Panel with High Impedance (Hi-z) Monitoring Ports
16 x E1, 120 Ohms, 16 Port Patch Panel with High Impedance (Hi-z) Monitoring Ports is primarily designed for applications where E1 circuits are required to be "patched" as well as simultaneously "tapped" for non-intrusive monitoring applications. Available in 19 Inch Rack Mount.
Read More... Data Sheet16 E1, 75 Ohms, Patch Panel with High Impedance (Hi-z) Monitoring Ports
16 x E1, 75 Ohms, 16 Port Patch Panel with High Impedance (Hi-z) Monitoring Ports is primarily designed for applications where E1 circuits are required to be "patched" as well as simultaneously "tapped" for non-intrusive monitoring applications. 75 Ohms Patch Panels with High Impedance (Hi-z) Monitoring Ports are available with various 75 Ohms BNC, BT43, M4 (Male), M4 (Female), Siemens (1.6/5.6 Female) Connector options.
Read More... Data Sheet16 T1, 100 Ohms, Patch Panel with High Impedance (Hi-z) Monitoring Ports
16 x T1, 100 Ohms, 16 Port Patch Panel with High Impedance (Hi-z) Monitoring Ports is primarily designed for applications where T1 circuits are required to be "patched" as well as simultaneously "tapped" for non-intrusive monitoring applications. Available in 19 Inch Rack Mount.
Read More... Data Sheet16 E1 G.703, 120 Ohms (RJ45) to E1 75 Ohms (BNC Female) Converter Balun Panel
16 E1, G.703 balun panel with 120 Ohms (RJ45) to E1, 75 Ohms (BNC Female Connector) converter panel, may be used to convert up to 16, E1, 120 Ohms balanced (RJ45) Interfaces to E1, 75 Ohms un-balanced (BNC Female Connector) Interfaces. 19 Inch Rack Mount.
Read More... Data Sheet 16 E1, G.703, 120 Ohms (RJ45) to E1, 75 Ohms
(1.6 / 5.6 Female Connector) Converter Balun Panel
16 E1, G.703 balun panel with 120 Ohms (RJ45) to E1, 75 Ohms (1.6 / 5.6 Female Connector) converter panel, may be used to convert up to 16, E1, 120 Ohms (RJ45) Interfaces to E1, 75 Ohms (1.6 / 5.6 Female Connector) Interfaces. 19 Inch Rack Mount.
Read More... Data Sheet 16 E1, G.703, 120 Ohms (RJ45) to E1, 75 Ohms
(BT43 Male Connector) Converter Balun Panel
16 E1, G.703 balun panel with 120 Ohms (RJ45) to E1, 75 Ohms (BT43 Male Connector) converter panel, may be used to convert up to 16, E1, 120 Ohms (RJ45) Interfaces to E1, 75 Ohms (BT43 Male Connector) Interfaces. 19 Inch Rack Mount.
Read More... Data Sheet 16 E1, G.703, 120 Ohms (RJ45) to E1, 75 Ohms
(M4 Female Connector) Converter Balun Panel
16 E1, G.703 balun panel with 120 Ohms (RJ45) to E1, 75 Ohms (M4 Female Connector) converter panel, may be used to convert up to 16, E1, 120 Ohms (RJ45) Interfaces to E1, 75 Ohms (M4 Female Connector) Interfaces. 19 Inch Rack Mount.
Read More... Data Sheet 16 E1, G.703, 120 Ohms (RJ45) to E1, 75 Ohms
(M4 Male Connector) Converter Balun Panel
16 E1, G.703 balun panel with 120 Ohms (RJ45) to E1, 75 Ohms (M4 Female Connector) converter panel, may be used to convert up to 16, E1, 120 Ohms (RJ45) Interfaces to E1, 75 Ohms (M4 Female Connector) Interfaces. 19 Inch Rack Mount.
Read More... Data SheetDual Balun (Shielded) 2 x BNC (F) (75 Ohms) to RJ-45 (F) 120 Ohms Converter
Dual Balun (Shielded) 2 x BNC (F) (75 Ohms) to RJ-45 (F) 120 Ohms Converter
Read More... Data SheetAC to DC Converter - Universal AC Mains to 48V DC converter. 3.2 Amps 150 Watts 4 fuse protected outputs. (19 Inch Rack Mount Version)
AC to DC converter may be used to convert 85V AC-264V AC, 47Hz-63Hz AC Mains Input Voltage to 48V DC output voltage. It may be also used to convert 120V DC - 370V DC Input Voltage to 48V DC Output Voltage. Available with 3.2 Amps (150 Watts). 4 fuse protected outputs. 19 Inch Rack Mount Version.
Read More... Data SheetAC to DC Converter - Rack Mounting Version 48V DC, 10.5 Amps, 500 Watts, 4 Fuse Protected Outputs
Valiant’s AC to DC converter may be used to convert 85V AC-264V AC, 47Hz-63Hz AC Mains Input Voltage to 48 V DC output voltage. It may be also used to convert 120 V DC - 373 V DC Input Voltage to 48 V DC Output Voltage.
Read More... Data Sheet AC to DC Converter - Universal AC Mains to 24V DC
(19 Inch Rack Mount Version)
AC to DC converter may be used to convert 85V AC-264V AC, 47Hz-63Hz AC Mains Input Voltage to 24V DC output voltage. It may be also used to convert 120V DC - 370V DC Input Voltage to 24V DC Output Voltage. Available with 6.3 Amps (150 Watts), 4 fuse protected outputs. 19 Inch Rack Mount Version.
Read More... Data SheetDC to DC Converter - 48V DC to 24V DC (19 Inch Rack Mount Version)
DC to DC Converter - 48V DC (range DC 36-76) to 24V DC converter. This DC to DC converter may be used to convert 48V DC (range 36V DC to 76V DC) Main Input Voltage to 24V DC output voltage. Available with 4.2 Amps (100 Watts) with 4 fuse protected outputs. 19 Inch Rack Mount Version.
Read More... Data SheetDC to DC Converter - 48V DC, 21.0 Amps, 1000 Watts, 4 Fuse Protected Outputs, Rack Mounting Version
DC to DC converter may be used to convert 90V DC ~ 373V DC Input Voltage to 48V DC output voltage. It may be also used to convert 85V AC-264V AC, 47Hz-63Hz AC Mains Input Voltage to 48V DC Output Voltage. The DC to DC converter is designed for telecom applications requiring stable DC voltage with low EMI and EMC interference. This is an external converter power supply which is available in 19 inch rack mount version, with four fuse protected outputs.
Read More... Data Sheet16 x E1 (120 Ohms) Splitter Panel
What does it do?
The 16 x E1 (120 Ohms) Splitter “Splits” the E1 signal that it receives between two E1 ports,
by monitoring the same E1 signal on two ports, simultaneously.
16 x T1 (100 Ohms) Splitter Panel
What does it do?
The 16 x T1 (100 Ohms) Splitter “Splits” the T1 signal that it receives between two T1 ports, by monitoring
the same T1 signal on two ports, simultaneously.
Valiant Communications is an ISO 9001:2015, ISO 10001:2018, ISO 14001:2015, ISO 27001:2022 and ISO 45001:2018 certified equipment manufacturer.
Links
Products
Teleprotection over E1, C37.94,
MPLS-TP, MPLS / IP, IEC-61850 GOOSE
VCL-PMU-30, Phasor Measurement Unit (PMU)
VCL-PDC, Phasor Data Concentrator (PDC)
Products
GPS / GNSS, Primary Reference Clocks (G.811)
PTP IEEE-1588v2 Grandmaster, PTP Slave, PTP Transparent Clock
GPS to IRIG-B, GPS to 1PPS Servers
Time Distribution, IRIG-B, 1PPS, RS-232 / RS-485
SDH with MPLS-TP & SONET Multiplexers
E1 PDH & Digital Cross Connect
Products
IP over TDM / Ethernet over TDM
TDM over IP / Ethernet / Packet / MPLS
E1 / T1, 1+1 Automatic Protection / Failover
1+1 Ethernet Failover / AB Fallback Switch
Groomer (Hi-Z Non-Intrusive Monitoring) - E1, T1 and STM-1
E1 and T1 Echo Cancellers & VQE
Serial to Ethernet and MODBUS Converters